CATALOG
UNGROUPED/NO FUEL FUEL/DAFT-2

Dust and Aerosol Measurement Feasibility Test - 2 (DAFT-2)

Detection
Spacecraft cabinSpace station
AI summary
AI-GENERATED

Generated from the curated record only. The model is instructed not to invent numbers; verify all values against the source before engineering use.

Experimental setup

FUEL

Phase
No fuel
Material
Ambient ISS airborne particulate and released test particles
Shape
Airborne aerosol sampling
Size
Not specified

CONDITIONS

O2 concentration
Varied / not specified
Pressure
Varied / not specified
Airflow
Varied / not specified

Single values are documented test conditions, not flammability limits. Ranges appear under variables tested.

OBJECTIVES

Continue the DAFT particle-counting campaign on ISS to build a more representative particulate baseline for spacecraft smoke-detector design.

Sensors & measurements
  • P-Trak ultrafine particle counter
  • Isopropyl-alcohol condensation chamber
  • Light-beam particle detector
Variables tested
  • Repeatability of microgravity particle counts
  • Ambient particulate variability across ISS locations
  • Detector discrimination between dust and smoke-sized aerosol
Key findings
  1. 01Extended the DAFT aerosol measurements with additional ISS test points.
  2. 02Reinforced the finding that on-orbit particulate sizes can exceed typical ground values.
  3. 03Provided background data needed for detectors that must distinguish dust from smoke.