CATALOG
UNGROUPED/NO FUEL FUEL/DAFT
Dust and Aerosol Measurement Feasibility Test (DAFT)
Detection
Spacecraft cabinSpace stationAI summary
AI-GENERATEDStreaming from your endpoint...
Generated from the curated record only. The model is instructed not to invent numbers; verify all values against the source before engineering use.
Experimental setup
FUEL
- Phase
- No fuel
- Material
- Ambient ISS airborne particulate and released test particles
- Shape
- Airborne aerosol sampling
- Size
- Not specified
CONDITIONS
- O2 concentration
- Varied / not specified
- Pressure
- Varied / not specified
- Airflow
- Varied / not specified
Single values are documented test conditions, not flammability limits. Ranges appear under variables tested.
OBJECTIVES
Verify that a modified P-Trak ultrafine particle counter, a key SAME component, works in microgravity and can characterize ISS airborne particulate before SAME flew.
Sensors & measurements
- P-Trak ultrafine particle counter
- Isopropyl-alcohol condensation chamber
- Light-beam particle detector
Variables tested
- Ultrafine particle counts in microgravity
- Particle counter operation without gravity-driven alcohol return
- Ambient ISS particulate levels
Key findings
- 01Demonstrated a hand-held commercial particle counter in the ISS atmosphere.
- 02Data indicated low particulate levels relative to the Shuttle, consistent with the smaller ISS crew and its filtration system.
- 03Average particle sizes on orbit were larger than on Earth, possibly due to spacecraft filtration efficiency.
- 04Established the median particulate baseline needed to distinguish ordinary dust from dangerous smoke.